White Rodgers 1F85-277 Anleitung zur Fehlerbehebung Seite 128

  • Herunterladen
  • Zu meinen Handbüchern hinzufügen
  • Drucken
  • Seite
    / 134
  • Inhaltsverzeichnis
  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 127
S
y
stem Mode Indicator Power Indicator LED
HVAC Equipment
Connections
Automatic Resetting
Fuse
Zone Calling Indicators
Mounting Keyholes
Two at Top also.
Zone Terminal
Blocks for Zone
Dampers
24V Transformer
Terminal Blocks
Zone Terminal
Blocks for Zone
Thermostats
CLAS and COAS
Terminal Blocks
Sensor Limits
Installation
Operation
Set-Up for Various HVAC Equipment
Leaving Air Sensor
Outdoor Air Sensor
Timers
Checkout
Wiring
Troubleshooting
Wiring Diagram
INSTALLATION
The CMM-3U Control is a three (3) zone control panel that can be
used with conventional single stage, two stage heating and cool-
ing, heat pumps with or without dual fuel and up to three stages of
heating. The CMM-3U panel is the central control panel that all zone
dampers, zone thermostats, Heat Pump Controls, power transformer,
Outdoor Air Sensor and Leaving Air Sensor are wired.
When installing the CMM-3U panel it is important to pick a central
location where it is most convenient to bring all the wires. Most often
this is at the furnace or air handler. It is often the most convenient
location and closest to power, the HVAC unit controls and the zone
dampers when typically located at or near the plenum.
The CMM-3U panel case is made of sturdy ABS plastic and can
be mounted to any flat surface. It is recommended that the panel
be mounted to a wall or return plenum and NOT on the furnace or
plenum where it will be in contact with the excessive hot tempera-
tures.. The panel can be located in an attic space or in an enclosed
cabinet of a rooftop unit. Insure the panel is not in direct exposure to
the elements.
The cover easily removes from the case by pulling firmly and sepa-
rating the cover from the case exposing the circuit board. There are
4 key-hole mounting points in each corner of the case. The case
has openings in the rear of the case as well as the side for all wiring.
Wiring can come from the back as well as the side in order to make a
neat installation.
OPERATION
The CMM-3U can be controlled by conventional single stage or heat
pump thermostats. Each thermostat can then call for heating, cool-
ing or the fan. When a thermostat calls the panel will keep open the
damper to the calling zone, if not already open, close the dampers to
the zone(s) not calling and activate the appropriate HVAC equipment.
When opposite calls exist for both heating and cooling the panel will
allow the zones to automatically switch between the modes. When all
zones are
satisfied the panel then looks for individual fan calls from
any zone and controls the dampers based on these calls as well.
When all zone thermostats are not calling for heating, cooling or the
fan all dampers will return to a normally open position.
Once a call for either heating or cooling is made the panel will open
the damper(s) to the zone(s) calling, close the damper(s) to those
zones not calling, activate the appropriate controls for heating or
cooling, whichever is being called and not accept any calls for the
opposite mode.
Any calls for the opposite mode will be locked out until the initial
mode is either satisfied or a period of time has elapsed that is suffi-
cient for the first mode to satisfy, a maximum of 20 minutes. A unique
sequence determines the time the unit has been running or needs to
CMM-3U
CMM-3UKZONE PANEL