  • FEHLERBEHEBUNG
  • LESEZEICHEN
  • Bewertet. / 5. Basierend auf Kundenbewertungen
Seitenansicht 110
COMFORTPRO
AIR CLEANERS
AIR CLEANER
PROGRAMMING OPTIONS
Program Setting 8: Time without high voltage after
Service (Electronic Air Cleaners only)
In setting 8 STANDBY led will flash eight times every two
seconds.
Setting a specific time for no high voltage after servicing is
useful when the filter cells are damp or condensed in winter
time. This setting will go back to default value if power is
interrupted to the air cleaner.
Default: OFF (all leds are off), when the air cleaner is switched on,
there’s always high voltage on the cell(s).
• Press S: led • (LOW) will light up, meaning you’ve set the time of
no high voltage to 30 minutes.
• Press S: led •• (MEDIUM) will light up, meaning you’ve set the
time of no high voltage to 60 minutes.
• Press S: led ••• (HIGH) will light up, meaning you’ve set the time
of no high voltage to 120 minutes.
• Press S: led •••• (TURBO) will light up, meaning you’ve set the
time of no high voltage to 240 minutes.
If you want to go back to one of the previous time setting levels,
press T.
Press PROGRAM to confirm setting 8. The air cleaner will return
to the normal running mode.
Reset to factory default
To reset the factory default settings:
Open the inlet grid, press the panel button (>> ). While pressing the
panel button (>> ) close the inlet grid. Release the panel button (>> )
when you hear two beeps.
Everything is now back into the default setting, except the Service
Indicator (hours in use).
9 FILTER REPLACEMENT / CLEANING
In order to open the inlet grid (i.e. access the filter components), a
narrow round screwdriver type tool will be needed (such as a torx
type). The inlet grid is secured by two mechanical clips. To release
these clips there are two access holes parallel to the control board
faceplate on the inlet grid (approx. 3½” from the sides).
Insert the tool into the access holes and gently push further through
some light resistance. This will allow the clips to be “unlocked” and
thus the inlet grid will open easily.
DO NOT PULL THE DOOR OPEN WITHOUT RELEASING THE
CLIPS.
9.1 Prefilter replacement
The disposable prefilter can only be used once and cannot be
cleaned. Do not turn the prefilter around since it can only be used in
one flow direction.
9.2 Electronic filter cleaning
A crackling or snapping sound will be heard occasionally during use
of the air cleaner. This is normal and is caused by high voltage arc-
ing in the filter. Cleaning the electronic filter is necessary when the
crackling is heard frequently.
For maximum efficiency your air cleaner cell(s) should be
cleaned regularly.
www.white-rodgers.com