NOTE
Ifyouareprogrammingyourthermostatforthersttimeand
youwantprogrammingforalldaysoftheweektobethesame
asMonday’sprogram,pressRUNorHOLDatthispoint,and
proceedtoEnter Cooling Program.(ThissimpliedCOPYDAY
featureonlyworksthersttimeyouprogramyourthermostat.
Ifyouwanttocopyoneday’sprogrammingtoaspecicday
programming,refertoCOPY DAY FUNCTIONinOPERATING
FEATURES.Ifyouarechangingyourthermostat’sprogramming,
youmustprogrameachdayseparately.)
8. PressHOLDonce.TU(indicatingTuesdayprogram)willap-
pearinthedisplay,alongwiththestarttimeforthe1stheating
periodandthecurrentlyprogrammedtemperature.
9. Repeat steps 3 through 7 to completeTuesday’s heating
programming.
10.Continueenteringeachday’sprogramminguntilallheating
periodstimeandtemperatureshavebeenentered.
11.Whenyouhavecompletedenteringyourheatingprogram,
pressRUN.
Enter Cooling Program
If the outside temperature is below 50°F, disconnect power
to the cooling system before programming. Energizing
the air conditioner compressor during cold weather may
cause personal injury or property damage.
!
CAUTION
Reset Operation
Ifavoltagespikeorstaticdischargeblanksoutthedisplayor
causeserraticthermostatoperationyoucanresetthethermo-
stat by pressing
, andTIME at the same time.This
alsoresetsthefactorydefaultstothecongurationmenuand
TROUBLESHOOTING
program.Ifthethermostathaspower,hasbeenresetandstill
doesnotfunctioncorrectlycontactyourheating/coolingservice
personorplaceofpurchase.
Batteries
Foroptimumperformance,werecommendreplacingbatteries
onceayearwithfresh“AA”Energizer
®
alkalinebatteries.
1. MoveSYSTEMswitchtoCOOLposition.
2. Follow the procedure for entering your cooling program,
usingyourselectedcoolingtimesandtemperatures.
CHECK YOUR PROGRAMMING
Followthesestepstocheckyourthermostatprogrammingone
naltimebeforebeginningthermostatoperation.
1. MoveSYSTEMswitchtoHEATposition.
2. PressPRGMtoviewthe1stMondayheatingperiodtimeand
temperature.EachtimeyoupressPRGM,thenextheating
periodtimeandtemperaturewillbedisplayedinsequence
forMonday.PressHOLDtodisplayTuesday’s1stheating
period, and press PRGM to view each of the remaining
Tuesday’s heating period timeand temperatures.To view
eachday’sheatingprogram,pressHOLDtochangedayand
thempressPRGMtolookateachprogrammingperiodfor
theday.(Youmaychangeanytimeortemperatureduring
thisprocedure.)
3. PressRUN.
4. MoveSYSTEMswitchtoCOOLposition.
5. Repeatstep2tocheckcoolingprogram.
6. MoveSYSTEMswitchtoHEATorCOOLandpressRUNto
beginprogramoperation.
YOUR THERMOSTAT IS NOW COMPLETELY PROGRAMMED AND
READY TO PROVIDE MAXIMUM COMFORT AND EFFICIENCY!
OPERATION
Symptom Possible Cause Corrective Action
No Heat/No Cool/No Fan
(common problems)
Blownfuseortrippedcircuitbreaker.1.
FurnacepowerswitchtoOFF.2.
Furnaceblowercompartmentdoororpanel3.
looseornotproperlyinstalled.
Replacefuseorresetbreaker.
TurnswitchtoON.
Replacedoorpanelinproperpositiontoengage
safetyinterlockordoorswitch.
No Heat
Pilotlightnotlit.1.
SYSTEMSwitchnotsetto2. HEAT.
Looseconnectiontothermostatorsystem.3.
FurnaceLock-OutCondition.Heatmayalso4.
beintermittent.
HeatingSystemrequiresserviceor5.
thermostatrequiresreplacement.
Re-lightpilot.
SetSYSTEMSwitchtoHeat andraisesetpointabove
roomtemperature.
Verifythermostatandsystemwiresaresecurelyat-
tached.
Manyfurnaceshavesafetydevicesthatshutthesys-
temdownwhenalock-outconditionoccurs.Iftheheat
worksintermittentlycontactthefurnacemanufactureror
localservicepersonforassistance.
Diagnostic:SetSYSTEMSwitchtoHEATandraise
thesetpointaboveroomtemperature.Within afew
secondsthethermostatshouldmakeasoftclick
sound.Thissoundusuallyindicatesthethermostat
isoperatingproperly.Ifthethermostatdoesnotclick,
trytheresetoperationlistedabove.Ifthethermostat
doesnotclickafterbeingresetcontactyourheating
andcoolingservicepersonorplaceofpurchasefor
areplacement.Ifthethermostatclicks,contactthe
furnacemanufactureroraservicepersontoverifythe
heatingsystemisoperatingcorrectly.