Blue 2” Heat Pump Thermostat
Heat Pump Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
1F82-0261 Thermostat
Model Programming Choices
1F82-0261
5/1/1 Day Programmable
SPECIFICATIONS
Electrical Rating:
Battery Power or Hardwire ............................. 20 VAC, 50/60 Hz
Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could cause
a fire hazard.
WARNING
!
PART NO. 37-7022C
Replaces 37-7022B
1023
www.white-rodgers.com
www.emersonclimate.com
Index Page
Installation 2
Wiring Diagram 3
Thermostat Quick Reference 4
Installer Configuration Menu 5
Operation 6
Programming 7
Troubleshooting 9
THERMOSTAT APPLICATION GUIDE
Thermostat
Configuration
Options
Thermostat
Applications
Maximum
Stages
Heat/Cool
Heat Pump
Single Stage
Compressor
Single Stage Compressor
Heat Pump Systems – 1
Stage Aux/Emergency Heat
2/1
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - PRECAUTIONS

1Blue 2” Heat Pump ThermostatHeat Pump Installation and Operating InstructionsSave these instructions for future use!FAILURE TO READ AND FOLLOW A

Seite 2 - INSTALLATION

10STAGINGSecond Stage - Auxiliary HeatMost heat pump systems have an Auxiliary or Second Stage electric heater or gas furnace. Heat produced by a heat

Seite 4 - THERMOSTAT QUICK REFERENCE

12White-Rodgers is a division of Emerson Electric Co.The Emerson logo is a trademark and service mark of Emerson Electric Co.Homeowner Help Line: 1-

Seite 5 - INSTALLER/CONFIGURATION MENU

2REMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disconnected.2. R

Seite 6 - OPERATION

3INSTALLATION batteries should be replaced before leaving. When less than two months of battery life remain, the setpoint temperature will offse

Seite 7 - PROGRAMMING

4THERMOSTAT QUICK REFERENCE Before you begin programming your thermostat, you should be familiar with its features and with the display and the locati

Seite 8

5The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. To enter the menu: Set

Seite 9

6Emergency SystemEMER bypasses the Heat Pump to use the heat source wired to terminal W2 on the thermostat. EMER is typically used when compressor op

Seite 10 - TROUBLESHOOTING

7Do not allow the compressor to run unless the compressor oil heaters have been operational for 6 hours and the system has not been ope

Seite 11

8PROGRAMMING Enter Heating Program1. Move the SYSTEM switch to HEAT.2. Press PRGM once. “Mo Tu We Th Fr” (indicating weekday program) will appear in

Seite 12 - The Emerson logo is a

9TROUBLESHOOTING Reset OperationIf a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the