This thermostat is intended for use with a low voltage NEC
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualifi ed heating and air
conditioning contractor or electrician.
Do not exceed the specifi cation ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Blue 2” Single Stage Thermostat
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
For use with the following Class II systems:
• Single Stage systems
Single-stage heat pump systems with no Aux heat
DO NOT USE WITH:
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
1F80-0261 Thermostat
Model Programming Choices
1F80-0261
5/1/1 Day Programmable
SPECIFICATIONS
Electrical Rating:
Battery Power ................................................. mV to 30 VAC, 50/60 Hz or DC
Input-Hardwire ................................................ 20 to 30 VAC
Terminal Load ........................................................ 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range ...................................................... 45° to 90°F (7° to 32°C)
Differential (Single Stage) ...................................... Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) ........................................ Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient ................................................. 32° to +105°F (0° to +41°C)
Operating Humidity ................................................ 90% non-condensing max.
Shipping Temperature Range ................................ -40° to +150°F (-40° to +65°C)
Dimensions Thermostat ......................................... 3-3/4”H x 4-3/4”W x 1-1/2”D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specifi ed voltage.
Higher voltage will damage control and could cause
shock or fi re hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could
cause a fi re hazard.
WARNING
!
PART NO. 37-7009B
Replaces 37-7009A
0917
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Replaces 37-7009A

www.white-rodgers.comThis thermostat is intended for use with a low voltage NEC Class II system. Do not use this thermostat with a line voltage system

Seite 4 - THERMOSTAT QUICK REFERENCE

www.white-rodgers.comWhite-Rodgers is a divisionof Emerson Electric Co.The Emerson logo is a trademark and service markof Emerson Electric Co.Homeowne

Seite 5 - INSTALLER/CONFIGURATION MENU

2INSTALLATION REMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installation is complete. Ensure that electrical power is disco

Seite 6

3ENERGY MANAGEMENT RECOVERY (EMR)When the EMR feature is activated the thermostat’s microcomputer calculates the time it will take to change the room

Seite 7 - PROGRAMMING

4WIRING DIAGRAMS RCG WFigure 4. Typical wiring diagram for two transformer single stage systems with safety circuits in BOTH systemsChangeoverRelay*YO

Seite 8

5The confi guration menu allows you to set certain thermostat operating characteristics to your system or personal requirements. To enter the menu: Set

Seite 9 - TROUBLESHOOTING

6Cooling System1. Move SYSTEM switch to COOL position.2. Press to adjust thermostat setting below room temperature. The blower should come on immed

Seite 10

7PROGRAMMING PROGRAMMING YOUR THERMOSTATThis section will help you plan your thermostat’s program to meet your needs. For maximum comfort and effi cien

Seite 11

88. Press PRGM once. “SA” (indicating Saturday program) will appear in the display, along with the start time for the 1st heating period and the curr

Seite 12 - The Emerson logo is a

9TROUBLESHOOTING Reset OperationIf a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, reset the thermo