Description
Gas or Oil Heat Yes
Electric Furnace Yes
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (with Aux. or Emergency Heat) No
Systems with up to 3 Stages Heat, 2 Stages Cool No
Heat Only Systems Yes
Millivolt Heat Only Systems – Floor or Wall Furnaces Yes
Cool Only Systems Yes
Hydronic (Hot Water) Zone Heat – 2 Wires Yes
Hydronic (Hot Water) Zone Heat – 3 Wires Yes
www.white-rodgers.com
Blue Selecto Thermostat with
Automatic Heat/Cool Changeover Option
PART NO. 37-6952B
Replaces 37-6952A
0905
Single Stage or Heat Pump
Installation and Operating Instructions for Model:
APPLICATIONS
THERMOSTAT APPLICATION GUIDE
1F80ST-0471 Thermostat
with Spanish Display
SPECIFICATIONS
Electrical Rating:
Battery Power . . . . . . . . . . . . . . . . . . . . . . . . . . mV to 30 VAC, NEC Class II, 50/60 Hz or DC
Input-Hardwire . . . . . . . . . . . . . . . . . . . . . . . . . 20 to 30 VAC
Terminal Load . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1.0 A per terminal, 1.5A maximum all terminals combined
Setpoint Range . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45° to 90°F (7° to 32°C)
Differential (Single Stage) . . . . . . . . . . . . . . . . . . . . Heat 0.6°F; Cool 1.2°F (adjustable)
Differential (Heat Pump) . . . . . . . . . . . . . . . . . . . . . Heat 1.2°F; Cool 1.2°F (adjustable)
Operating Ambient. . . . . . . . . . . . . . . . . . . . . . . . . . 32° to +105°F (0° to +41°C)
Operating Humidity . . . . . . . . . . . . . . . . . . . . . . . . . 90% non-condensing max.
Shipping Temperature Range . . . . . . . . . . . . . . . . . -40° to +150°F (-40° to +65°C)
Dimensions Thermostat. . . . . . . . . . . . . . . . . . . . . . 3.4"H x 4.4"W x 1.3"D
CAUTION
!
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or circuit
breaker box until installation is complete.
ATTENTION: MERCURY NOTICE
This product does not contain mercury. However, this
product may replace a product that contains mercury.
Mercury and products containing mercury must not be
discarded in household trash. Do not touch any spilled
mercury. Wearing non-absorbent gloves, clean up any
spilled mercury and place in a sealed container. For proper
disposal of a product containing mercury or a sealed
container of spilled mercury, place it in a suitable shipping
container. Refer to www.white-rodgers.com for location to
send product containing mercury.
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
Model Programming Choices
1F80ST-0471
5/2 Day 5/1/1 Day Non-Programmable
1F86ST-0471
Non-Programmable
Save these instructions for future use!
Index Page
Installation 2
Wiring Connections 3
Thermostat Quick Reference 3
Installer Confi guration Menu 4
Operating Your Thermostat 6
Programming 6
Troubleshooting 8
Seitenansicht 0
1 2 3 4 5 6 7 8

Inhaltsverzeichnis

Seite 1 - SPECIFICATIONS

DescriptionGas or Oil Heat YesElectric Furnace YesHeat Pump (No Aux. or Emergency Heat) YesHeat Pump (with Aux. or Emergency Heat) NoSystems with up t

Seite 2 - INSTALLATION

2WARNING!Thermostat installation and all components of the control system shall conform to Class II circuits per the NEC code.INSTALLATION Re

Seite 3 - WIRING CONNECTIONS

3Displays the power level of the2 “AA” batteries: indicates good power level. indicates batteries at abouthalf power. “Cambiar ” (Ch

Seite 4 - INSTALLER/CONFIGURATION MENU

4INSTALLER/CONFIGURATION MENU With thermostat in Heat, Cool or Auto, in normal operation, press the Menu button for at least 5 seconds. The display wi

Seite 5

5INSTALLER/CONFIGURATION MENU 4. Energy Management Recovery: (this step is skipped ifconfi gured to be non-programmable). Energy Management Recovery

Seite 6

6OPERATING YOUR THERMOSTAT IMPORTANT! Choose the Vent Setting (Auto or On)Set the VENT Switch to Auto or On.Vent Auto is the most commonly selected

Seite 7

7Energy Saving Factory Pre-ProgramThe 1F80ST-0471 thermostats are programmed with the energy saving settings shown in the table below for all days of

Seite 8 - TROUBLESHOOTING

Symptom Possible Cause Corrective ActionNo Heat/No Cool/No Fan (common problems)1. Blown fuse or tripped circuit breaker.2. Furnace power switch to OF