WHITE-RODGERS DIVISION
EMERSON ELECTRIC CO.
9797 REAVIS ROAD
ST. LOUIS, MISSOURI 63123-5398
1F80-24
Programmable Electronic Digital Thermostat
INSTALLATION AND
OPERATION INSTRUCTIONS
Printed in U.S.A.
PART NO. 37-5287E
Replaces 37-5287D
9901
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS CAREFULLY
BEFORE INSTALLING OR OPERATING THIS CONTROL COULD CAUSE
PERSONAL INJURY AND/OR PROPERTY DAMAGE.
DESCRIPTION
Your new White-Rodgers Digital Thermostat uses the technol-
ogy of a solid-state microcomputer to provide precise time/
temperature control. This thermostat offers you the flexibility to
design heating and cooling programs that fit your needs.
Features:
Battery powered (3 “AA” Energizer
®
alkaline batteries in-
cluded)
Same program for all days of the week
Simultaneous heat and cool program storage
Four separate time/temperature settings per program
Preprogrammed temperature control
LCD continuously displays set point, and alternately dis-
plays time and room temperature
Temperature override until next program period
Manual program override (HOLD temperature)
User may select either 12- or 24-hour clock display
°F/°C convertibility
Temperature range 45° to 90°F
Standard five terminals for single or dual transformer
systems
B & O terminals for single stage heat pumps or damper
operation
WHITE-RODGERS
SPECIFICATIONS
ELECTRICAL DATA
Electrical Rating:
8 to 30 VAC 50/60 Hz. or D.C.
0.05 to 1.5 Amps (Load per terminal)
1.5 Amps Maximum Total Load (All terminals combined)
THERMAL DATA
Setpoint Temperature Range:
45°F to 90°F (7°C to 32°C)
Operating Ambient Temperature Range:
32°F to 105°F
Operating Humidity Range:
0 to 90% RH (non-condensing)
Shipping Temperature Range:
-40°F to 150°F
APPLICATIONS
For use with:
Standard heat/cool or heat only systems
Electric heat systems
Gas or oil fired systems
Gas systems with intermittent ignition devices (I.I.D.) and/
or vent dampers
Hydronic (hot water or steam) systems
Single-stage heat pump systems
Millivolt systems
DO NOT USE WITH:
Multi-stage systems
Systems exceeding 30 VAC and 1.5 amps
3-wire zoned hydronic heating systems
PRECAUTIONS
Operator: Save these instructions for future use!
This thermostat is intended for use with a low voltage system; do
not use this thermostat with a line voltage system. If in doubt
about whether your wiring is millivolt, line, or low voltage, have
it inspected by a qualified heating and air conditioning contractor
or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes and
ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could cause
the control to malfunction.
To prevent electrical shock and/or equipment dam-
age, disconnect electric power to system at main fuse
or circuit breaker box until installation is complete.
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
CAUTION
!
WARNING
!
Seitenansicht 0
1 2 3 4 5 6

Inhaltsverzeichnis

Seite 1 - WHITE-RODGERS

WHITE-RODGERS DIVISIONEMERSON ELECTRIC CO.9797 REAVIS ROADST. LOUIS, MISSOURI 63123-53981F80-24Programmable Electronic Digital ThermostatINSTALLATION

Seite 2 - INSTALLATION

2INSTALLATIONREMOVE OLD THERMOSTAT1. Shut off electricity at the main fuse box until installation iscomplete. Ensure that electrical power is disconne

Seite 3 - CHECK THERMOSTAT OPERATION

3CHECK THERMOSTAT OPERATIONIf at any time during testing your system does not operateproperly, contact a qualified serviceperson.Fan OperationIf your

Seite 4 - OPERATION

4Cooling SystemThis thermostat has a built-in short-term (5-minute) time delay.This feature is activated after the compressor shuts down andthe setpoi

Seite 5 - PROGRAMMING YOUR THERMOSTAT

5OPERATING FEATURESNow that you are familiar with the thermostat buttons anddisplay, read the following information to learn about the manyfeatures of

Seite 6 - CHECK YOUR PROGRAMMING

Entering Your ProgramFollow these steps to enter the heating and cooling programsyou have selected.Set Current Time and Day1. Press SET TIME button on