This thermostat is intended for use with a low voltage NEC
Class II system. Do not use this thermostat with a line voltage
system. If in doubt about whether your wiring is millivolt, line,
or low voltage, have it inspected by a qualified heating and air
conditioning contractor or electrician.
Do not exceed the specification ratings.
All wiring must conform to local and national electrical codes
and ordinances.
This control is a precision instrument, and should be handled
carefully. Rough handling or distorting components could
cause the control to malfunction.
Blue 2” Single Stage Thermostat
Installation and Operating Instructions
Save these instructions for future use!
FAILURE TO READ AND FOLLOW ALL INSTRUCTIONS
CAREFULLY BEFORE INSTALLING OR OPERATING THIS
CONTROL COULD CAUSE PERSONAL INJURY AND/OR
PROPERTY DAMAGE.
APPLICATIONS
For use with the following Class II systems:
• SingleStagesystems
• Single-stageheatpumpsystemswithnoAuxheat
DO NOT USE WITH:
• Systemsexceeding30VACand1.5amps
• 3-wirezonedhydronicheatingsystems
1F87-0261 Thermostat
Model Programming Choice
1F87-0261
7 Day Programmable
SPECIFICATIONS
Electrical Rating:
Battery Power ................................................. mVto30VAC,50/60HzorDC
Input-Hardwire ................................................ 20to30VAC
Terminal Load ........................................................ 1.0Aperterminal,1.5Amaximumallterminalscombined
SetpointRange ...................................................... 45°to90°F(7°to32°C)
Differential(SingleStage) ...................................... Heat0.6°F;Cool1.2°F(adjustable)
Differential(HeatPump) ........................................ Heat1.2°F;Cool1.2°F(adjustable)
Operating Ambient ................................................. 32°to+105°F(0°to+41°C)
OperatingHumidity ................................................ 90%non-condensingmax.
ShippingTemperatureRange ................................ -40°to+150°F(-40°to+65°C)
Dimensions Thermostat ......................................... 3-3/4”Hx4-3/4”Wx1-1/2”D
PRECAUTIONS
To prevent electrical shock and/or equipment damage,
disconnect electric power to system at main fuse or
circuit breaker box until installation is complete.
CAUTION
!
Do not use on circuits exceeding specified voltage.
Higher voltage will damage control and could cause
shock or fire hazard.
Do not short out terminals on gas valve or primary
control to test. Short or incorrect wiring will damage
thermostat and could cause personal injury and/or
property damage.
Thermostat installation and all components of the
system shall conform to Class II (current limited)
circuits per the NEC code. Failure to do so could
cause a fire hazard.
WARNING
!
PART NO. 37-7038B
Replaces37-7038A
0950
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - Replaces37-7038A

www.white-rodgers.comThis thermostat is intended for use with a low voltage NEC Class II system. Do not use this thermostat with a line voltage system

Seite 4 - THERMOSTAT QUICK REFERENCE

www.white-rodgers.comWhite-Rodgersisadivision of Emerson Electric Co.The Emerson logo is a trademark and service mark of Emerson Electric Co.Homeo

Seite 5 - INSTALLER/CONFIGURATION MENU

2INSTALLATION REMOVE OLD THERMOSTAT1. Shutoffelectricityatthemainfuseboxuntilinstallationiscomplete. Ensure that electrical power is disco

Seite 6 - CHECK THERMOSTAT OPERATION

3ENERGY MANAGEMENT RECOVERY (EMR)When the EMR feature is activated the thermostat’smicrocomputer calculates the time it will take to c

Seite 7 - PROGRAMMING

4WIRING DIAGRAMS RCG WFigure 4. Typical wiring diagram for two transformer single stage systems with safety circuits in BOTH systemsChangeoverRelay*YO

Seite 8

5The configuration menu allows you to set certain thermostat operating characteristics to your system or personal requirements.Toentertheme

Seite 9 - TROUBLESHOOTING

6Cooling System1. MoveSYSTEMswitchtoCOOL position.2. Press  to adjust thermostat setting below roomtemperature. The blower should come

Seite 10

7PROGRAMMING PROGRAMMING YOUR THERMOSTATThis section will help you plan your thermostat’s programtomeet your needs. For maximum comfort and

Seite 11

84. PressTIMEonce(theprogrammedtimewillash).Press or until your selected time appears. The time will changein15minuteincrements.Wh

Seite 12 - The Emerson logo is a

9TROUBLESHOOTING Reset OperationIf a voltage spike or static discharge blanks out the display or causes erratic thermostat operation, r