@WHITE-RODGERS
1F85-277
Heating & Air Conditioning
7 Day/5-1-1 Programmable/Non-programmable, Auto
Changeover, Multi-Stage/Heat Pump Thermostat
INSTALLATION INSTRUCTIONS
FAILURE TO READ AND FOLLOWALL INSTRUCTIONS CAREFULLY BEFORE
INSTALLING OR OPERATING THIS CONTROL COULD CAUSE PERSONAL
INJURYAND/OR PROPERTY DAMAGE.
YOUR THERMOSTAT REPLACES
Description 1F85-277
Heat Pump (No Aux. or Emergency Heat) Yes
Heat Pump (with Aux. or Emergency Heat) Yes
Standard Heat& Cooling Systems Yes
Two Stage Heat& Two Stage Cool Yes
Standard Heat Only Systems Yes
Millivolt HeatOnly Systems - Floor or Wall Furnaces Yes
Standard Central Air Conditioning Yes
Gas or Oil Heat Yes
Electric Furnace Yes
Hydronic (Hot Water) Zone Heat- 2 Wires Yes
Hydronic (Hot Water) Zone Heat- 3 Wires No
PREPARATIONS
Assemble tools required as shown below.
HAND OR POWER
DRILL WITH 3/16 INCH
FLAT BLADE SCREWDRIVER
REMOVING OLD THERMOSTAT
To prevent electrical shock and/or equipment dam-
age, disconnectelectric power to systemat main fuse
or circuit breaker box until installation is complete.
Before removing wires from old thermostat's switching sub-
base, label each wire with the terminal designation it was
removed from.
1. Shut off electricity at the main fuse box until installation is
complete. Ensure that electrical power is disconnected.
2. Remove Old Thermostat: A standard heat/cool
thermostat consists of three basic parts:
a. The cover, which may be either a snap-on or
hinge type.
b. The base, which is removed by loosening all
captive screws.
c. The switching subbase, which is removed by
unscrewing the mounting screws that hold it on
the wall or adaptor plate.
3. Remove the front cover of the old thermostat. With
wires still attached, remove wall plate from the wall. If
the old thermostat has a wall mounting plate, remove the
thermostat and the wall mounting plate as an assembly.
4. Identify each wire attached to the old thermostat.
5. Disconnect the wires from the old thermostat one at a
time. DO NOT LET WIRES FALL BACK INTO THE
WALL.
6. Install new thermostat using the following procedures.
Mounting i
Hole
Mounting
Hole
Elec-Gas
witch
Figure 1 - Thermostat base
ATTENTION! This product does not contain mercury. How-
ever, this product may replace a unit which contains mercury.
Do not open mercury cells. If a cell becomes damaged, do not
touch any spilled mercury. Wearing non-absorbent gloves,
clean up the spilled mercury and place into a container which
can be sealed. If a cell becomes damaged, the unit should be
discarded.
Mercury must not be discarded in household trash. When the
unit this product is replacing is to be discarded, place in a
suitable container and return to White-Rodgers at 2895 Harrison
Street, Batesville, AR 72501 for proper disposal.
EMERSON,
Climat:e Ted mo_ogies
White-Rodgers is a division
of Emerson Electric Co.
www.white-rodgers.com
PART NO. 37-6560A
0430
Seitenansicht 0
1 2 3 4 5 6 ... 11 12

Inhaltsverzeichnis

Seite 1 - 1F85-277

@WHITE-RODGERS1F85-277Heating & Air Conditioning7 Day/5-1-1 Programmable/Non-programmable, AutoChangeover, Multi-Stage/Heat Pump ThermostatINSTALL

Seite 2 - SW'TC"/

OPERATIONheating program period appears. The time will change in 15-minute increments. When your selected time is displayed,press TIME again to return

Seite 3 - / , 2_bi 24VACRyHeating

TROUBLESHOOTINGSymptomNo Heat (continued)No CoolHeat, Cool or FanRuns ConstantlyPossible CauseFurnace(Air Conditioner)Cycles Too Fastor Too Slow (narr

Seite 4 - CHECKTHERMOSTAT OPERATION

TROUBLESHOOTINGSymptomForgot KeypadLockout Code (continued)Why won't my 2nd or3rd stage come on?Possible CauseFirst stage is keeping up with dema

Seite 5 - (I 15) e

MOUNTING AND WIRINGDo not use on circuits exceeding specified voltage.Higher voltage will damage control and could causeshock or fire hazard.Do not sh

Seite 6 - CONFIGURATION MENU

WIRING DIAGRAMS= IPolarity must be observed, tf the HOT side of the second transformeris jumpered to the COMMON side of the first transformer a short

Seite 7

Multi-Stage Terminal OutputsRefer to equipment manufacturers' instructions for specificsystem wiring information.You can configure the thermostat

Seite 8 - SPECIFICATIONS

Beforeyoubeginprogrammingyourthermostat,youshouldbefamiliarwithitsfeaturesandwiththedisplayandthelocationandoperationof thethermostatbuttons.Yourtherm

Seite 9

CONFIGURATION MENUPress the SYSTEM button until OFF is displayed, then press the (_ and (_ simultaneouslyINSTALLER/CONFIGURATION MENUPress Displayed P

Seite 10 - TROUBLESHOOTING

5) Select Energy Management Recovery OFF or ON -Energy Management Recovery (EMR) causes the thermo-stat to start heating or cooling early to make the

Seite 11

SPECIFICATIONSELECTRICAL DATAElectrical Rating:20 to 30 VAC 50/60 Hz or DC0.05 to 1.5 Amps (Load per terminal)2.5 Amps Maximum Total Load (All termina

Seite 12 - WHITE-RODGERS

PROGRAMMING YOURTHERMOSTATThis section will help you plan your thermostat's program tomeet your needs. For maximum comfort and efficiency, keep t